Skip to content
VuFind
  • 0 Items in e-Shelf (Full)
  • History
  • User Account
  • Logout
  • User Account
  • Help
    • English
    • Deutsch
  • Books & more
  • Articles & more
  • JuSER
Advanced
 
  • Literature Request
  • Cite this
  • Email this
  • Export
    • Export to RefWorks
    • Export to EndNoteWeb
    • Export to EndNote
    • Export to MARC
    • Export to MARCXML
    • Export to BibTeX
  • Favorites
  • Add to e-Shelf Remove from e-Shelf



QR Code

Test und Simulation von Detektorkomponenten des ASPIRIN-Detektors am Experiment ATRAP

Test und Simulation von Detektorkomponenten des ASPIRIN-Detektors am Experiment ATRAP

Goal of the ATRAP - Experiment is to capture the simplest atoms of antimatter, the Anti-Hydrogen-Atom $\overline{H}^{0}$ in a trap, where it can be cooled and detected in order to perform high precision optical spectroscopy. Subject of this work are studies in preparation of the construction of the...

More

Saved in:
Personal Name(s): Hofmann, M. W. (Corresponding author)
Contributing Institute: Publikationen vor 2000; PRE-2000; Retrocat
Imprint: Jülich Forschungszentrum Jülich, Zentralbibliothek, Verlag 1998
Physical Description: II, 93 p.
Document Type: Report
Book
Research Program: Addenda
Series Title: Berichte des Forschungszentrums Jülich 3572
Link: OpenAccess
OpenAccess
Publikationsportal JuSER
Please use the identifier: http://hdl.handle.net/2128/22617 in citations.

  • Description
  • Staff View
LEADER 03538nam a2200457 a 4500
001 864811
005 20210130002729.0
024 7 |a 2128/22617  |2 Handle 
037 |a FZJ-2019-04467 
041 |a German 
088 1 |a Juel-3572 
088 |a Juel-3572  |2 JUEL 
100 1 |a Hofmann, M. W.  |0 P:(DE-HGF)0  |b 0  |e Corresponding author 
245 |a Test und Simulation von Detektorkomponenten des ASPIRIN-Detektors am Experiment ATRAP 
260 |a Jülich  |c 1998  |b Forschungszentrum Jülich, Zentralbibliothek, Verlag 
300 |a II, 93 p. 
490 0 |a Berichte des Forschungszentrums Jülich  |v 3572 
520 |a Goal of the ATRAP - Experiment is to capture the simplest atoms of antimatter, the Anti-Hydrogen-Atom $\overline{H}^{0}$ in a trap, where it can be cooled and detected in order to perform high precision optical spectroscopy. Subject of this work are studies in preparation of the construction of the ASPIRIN-Detector being a realtime imaging Antihydrogen Annihilation Detector in the ATRAP - Experiment. Monte-Carlo-Simulations were performed in order to optimize efficiency and spatial resolution. Main part of the detector will be a cylindrical fibre hodoscope, consisting of several layers of differently oriented fibres allowing spatial resolution. Light output and attenuation length of the fibres were measured and the influence of low temperature was tested. 16-channel multi-anode photomultipliers for the fibre readout were tested, focussing an gain, crosstalk and dank counts. The perfomance of the tubes in magnetic field was studied. The following conclusions are drawn: The material between the annihilation point and the ASPIRIN-Detector should not exceed 3 mm copper, in order to maintain a satisfying spatial resolution. Scintillation does not freeze out under liquid - Helium - temperature, hence scintillating fibres are suitable for the Experiment. The fibres should not guide the light more then 1,5 m since the average attenuation length is of this order. The Photomultiplier tube H6568 of the manufacturer Hamamatsu is capable for the readout of the fibres, but raust be coated with magnetic shielding reducing the field to values below 10G. 
856 4 |y OpenAccess  |u http://juser.fz-juelich.de/record/864811/files/J%C3%BCl_3572_Hofmann.pdf 
856 4 |y OpenAccess  |x pdfa  |u http://juser.fz-juelich.de/record/864811/files/J%C3%BCl_3572_Hofmann.pdf?subformat=pdfa 
909 C O |o oai:juser.fz-juelich.de:864811  |p openaire  |p open_access  |p VDB  |p driver  |p dnbdelivery 
910 1 |a Forschungszentrum Jülich  |0 I:(DE-588b)5008462-8  |k FZJ  |b 0  |6 P:(DE-HGF)0 
913 1 |a DE-HGF  |b Programmungebundene Forschung  |l ohne Programm  |1 G:(DE-HGF)POF3-890  |0 G:(DE-HGF)POF3-899  |2 G:(DE-HGF)POF3-800  |v ohne Topic  |x 0  |4 G:(DE-HGF)POF  |3 G:(DE-HGF)POF3 
915 |a OpenAccess  |0 StatID:(DE-HGF)0510  |2 StatID 
980 |a report 
980 |a VDB 
980 |a UNRESTRICTED 
980 |a book 
980 |a I:(DE-Juel1)PRE2000-20140101 
980 1 |a FullTexts 
536 |a Addenda  |0 G:(DE-HGF)POF3-899  |c POF3-899  |f POF III  |x 0 
336 |a Book  |0 PUB:(DE-HGF)3  |2 PUB:(DE-HGF)  |m book 
336 |a Polo + 10  |0 10  |2 EndNote 
336 |a REPORT  |2 ORCID 
336 |a report  |2 DRIVER 
336 |a TECHREPORT  |2 BibTeX 
336 |a Report  |b report  |m report  |0 PUB:(DE-HGF)29  |s 1567150045_31679  |2 PUB:(DE-HGF) 
336 |a Output Types/Report  |2 DataCite 
920 |l yes 
920 |k Publikationen vor 2000; PRE-2000; Retrocat  |0 I:(DE-Juel1)PRE2000-20140101  |l Publikationen vor 2000  |x 0 
990 |a Hofmann, M. W.  |0 P:(DE-HGF)0  |b 0  |e Corresponding author 

  • Forschungszentrum Jülich
  • Central Library (ZB)
  • Powered by VuFind 6.1.1
Loading...