This title appears in the Scientific Report :
2024
Please use the identifier:
http://dx.doi.org/10.1088/2515-7639/ad1d8a in citations.
Please use the identifier: http://dx.doi.org/10.34734/FZJ-2024-01273 in citations.
Fourier transformation based analysis routine for intermixed longitudinal and transversal hysteretic data for the example of a magnetic topological insulator
Fourier transformation based analysis routine for intermixed longitudinal and transversal hysteretic data for the example of a magnetic topological insulator
We present a symmetrization routine that optimizes and eases the analysis of imperfect,experimental data featuring the anomalous Hall hysteresis. This technique can be transferred toany hysteresis with (point-)symmetric behavior. The implementation of the method isdemonstrated exemplarily using inte...
Saved in:
Personal Name(s): | Zimmermann, Erik (Corresponding author) |
---|---|
Schleenvoigt, Michael / Rupp, Alina / Behner, Gerrit / Karthein, Jan / Teller, Justus / Schüffelgen, Peter / Lüth, Hans / Grützmacher, Detlev / Schäpers, Thomas | |
Contributing Institute: |
Halbleiter-Nanoelektronik; PGI-9 |
Published in: | JPhys materials, 7 (2024) 1, S. 015015 - |
Imprint: |
Bristol
IOP Publishing
2024
|
DOI: |
10.1088/2515-7639/ad1d8a |
DOI: |
10.34734/FZJ-2024-01273 |
Document Type: |
Journal Article |
Research Program: |
Exploratory Qubits |
Subject (ZB): | |
Link: |
OpenAccess |
Publikationsportal JuSER |
Please use the identifier: http://dx.doi.org/10.34734/FZJ-2024-01273 in citations.
We present a symmetrization routine that optimizes and eases the analysis of imperfect,experimental data featuring the anomalous Hall hysteresis. This technique can be transferred toany hysteresis with (point-)symmetric behavior. The implementation of the method isdemonstrated exemplarily using intermixed longitudinal and transversal data obtained from achromium-doped ternary topological insulator revealing a clear hysteresis. Furthermore, byintroducing a mathematical description of the anomalous Hall hysteresis based on the errorfunction precise values of the height and coercive field are determined. |