In this study, the reliability of FDS+Evac (FDS 6.0.1, Evac 2.4.1) is investigated by a series of well-controlled laboratory experiments. The parameters controlling the free speed and the anisotropy of social force between pedestrians are calibrated based on the experimental values. With the adjuste...
Saved in:
Personal Name(s): | Liao, Weichen (Corresponding Author) |
---|---|
Chraibi, Mohcine / Seyfried, Armin / Zhang, Jun / Zheng, Xiaoping / Zhao, Ying | |
Contributing Institute: |
Jülich Supercomputing Center; JSC |
Published in: |
17th International IEEE Conference on Intelligent Transportation Systems (ITSC) |
Imprint: |
IEEE
2014
|
Physical Description: |
554-559 |
DOI: |
10.1109/ITSC.2014.6957748 |
Conference: | 2014 IEEE 17th International Conference on Intelligent Transportation Systems (ITSC), Qingdao (China), 2014-10-08 - 2014-10-11 |
Document Type: |
Contribution to a book Contribution to a conference proceedings |
Research Program: |
Computational Science and Mathematical Methods |
Publikationsportal JuSER |
In this study, the reliability of FDS+Evac (FDS 6.0.1, Evac 2.4.1) is investigated by a series of well-controlled laboratory experiments. The parameters controlling the free speed and the anisotropy of social force between pedestrians are calibrated based on the experimental values. With the adjusted values of the parameters, FDS+Evac is able to reproduce the experimental process with respect to the flow through the bottleneck. However, other pedestrian characteristics in the simulations do not match with those in the experiments. This study shows that the validation of FDS+Evac should not only consider single pedestrian characteristics. More careful calibration of parameters and comprehensive analysis are necessary before FDS+Evac is used for security-related applications in general. |