Linear Plasma Device PSI-2 for Plasma-Material Interaction Studies
Linear Plasma Device PSI-2 for Plasma-Material Interaction Studies
The linear plasma device PSI-2 serves as a pilot experiment for the development of components, operational regimes and control systems for the linear plasma device JULE-PSI, which will be located in the nuclear environment allowing studies of radioactive and toxic samples. PSI-2 is also used for fus...
Saved in:
Personal Name(s): | Kreter, Arkadi (Corresponding author) |
---|---|
Brand, C. / Huber, Alexander / Kraus, Sebastian / Möller, Sören | |
Contributing Institute: |
Plasmaphysik; IEK-4 |
Published in: | Fusion science and technology, 68 (2015) 1, S. 8-14 |
Imprint: |
La Grange Park, Ill.
American Nuclear Society
2015
|
DOI: |
10.13182/FST14-906 |
Document Type: |
Journal Article |
Research Program: |
Plasma-Wall-Interaction |
Link: |
Published on 2017-03-20. Available in OpenAccess from 2018-03-20. Get full text Published on 2017-03-20. Available in OpenAccess from 2018-03-20. Get full text |
Publikationsportal JuSER |
Please use the identifier: http://hdl.handle.net/2128/24706 in citations.
The linear plasma device PSI-2 serves as a pilot experiment for the development of components, operational regimes and control systems for the linear plasma device JULE-PSI, which will be located in the nuclear environment allowing studies of radioactive and toxic samples. PSI-2 is also used for fusion reactor relevant plasma-material interaction studies. This contribution describes the PSI-2 layout and parameters and summarizes the recent scientific and technical progress in the project, including the installation of a target station for the sample manipulation and analyses. |