Characterisation of capacitive field-effect sensors with a nanocrystalline-diamond film as transducer material for multi-parameter sensing
Characterisation of capacitive field-effect sensors with a nanocrystalline-diamond film as transducer material for multi-parameter sensing
The feasibility of a capacitive field-effect EDIS (electrolyte-diamond-insulator-semiconductor) platform for multi-parameter sensing is demonstrated by realising EDIS sensors with an O-terminated nanocrystalline-diamond (NCD) film as transducer material for the detection of pH and penicillin concent...
Saved in:
Personal Name(s): | Abouzar, M. H. |
---|---|
Poghossian, A. / Razavi, A. / Williams, O.A. / Bijnens, N. / Wagner, P. / Schöning, M. J. | |
Contributing Institute: |
Institut für Bio- und Nanosysteme - Bioelektronik; IBN-2 JARA-FIT; JARA-FIT |
Published in: | Biosensors and bioelectronics, 24 (2009) S. 1298 - 1304 |
Imprint: |
Amsterdam [u.a.]
Elsevier Science
2009
|
Physical Description: |
1298 - 1304 |
PubMed ID: |
18801654 |
DOI: |
10.1016/j.bios.2008.07.056 |
Document Type: |
Journal Article |
Research Program: |
Grundlagen für zukünftige Informationstechnologien |
Subject (ZB): | |
Publikationsportal JuSER |
The feasibility of a capacitive field-effect EDIS (electrolyte-diamond-insulator-semiconductor) platform for multi-parameter sensing is demonstrated by realising EDIS sensors with an O-terminated nanocrystalline-diamond (NCD) film as transducer material for the detection of pH and penicillin concentration as well as for the label-free electrical monitoring of adsorption and binding of charged macromolecules, like polyelectrolytes. The NCD films were grown on p-Si-SiO(2) substrates by microwave plasma-enhanced chemical vapour deposition. To obtain O-terminated surfaces, the NCD films were treated in an oxidising medium. The NCD-based field-effect sensors have been characterised by means of constant-capacitance method. The average pH sensitivity of the O-terminated NCD film was 40 mV/pH. A low detection limit of 5 microM and a high penicillin G sensitivity of 65-70 mV/decade has been obtained for an EDIS penicillin biosensor with the adsorptively immobilised enzyme penicillinase. Alternating potential changes, having tendency to decrease with increasing the number of adsorbed polyelectrolyte layers, have been observed after the layer-by-layer deposition of polyelectrolyte multilayers, using positively charged PAH (poly (allylamine hydrochloride)) and a negatively charged PSS (poly (sodium 4-styrene sulfonate)) as a model system. The response mechanism of the developed EDIS sensors is discussed. |