This title appears in the Scientific Report :
2006
18F-CPFPX PET: On the generation of parametric images and the effect of scan duration
18F-CPFPX PET: On the generation of parametric images and the effect of scan duration
8-cyclopentyl-3-(3-F-18-fluoropropyl)-1-propylxanthine (F-18-CPFPX) is a novel PET ligand for in vivo quantification of cerebral A, adenosine receptors. The present study investigated the applicability of voxelwise graphical analysis to the generation of parametric images of the total volume of dist...
Saved in:
Personal Name(s): | Meyer, P. T. |
---|---|
Elmenhorst, D. / Matusch, A. / Winz, O. / Zilles, K. / Bauer, A. | |
Contributing Institute: |
Institut für Medizin; IME JARA-BRAIN; JARA-BRAIN |
Published in: | Journal of nuclear medicine, 47 (2006) S. 200 - 207 |
Imprint: |
New York, NY
Society of Nuclear Medicine
2006
|
Physical Description: |
200 - 207 |
Document Type: |
Journal Article |
Research Program: |
Funktion und Dysfunktion des Nervensystems |
Series Title: |
Journal of Nuclear Medicine
47 |
Subject (ZB): | |
Publikationsportal JuSER |
8-cyclopentyl-3-(3-F-18-fluoropropyl)-1-propylxanthine (F-18-CPFPX) is a novel PET ligand for in vivo quantification of cerebral A, adenosine receptors. The present study investigated the applicability of voxelwise graphical analysis to the generation of parametric images of the total volume of distribution (DVt) of F-18-CPFPX as a prerequisite for voxel-by-voxel statistical analysis. The benefit of spatial smoothing for reduction of noise-dependent negative bias in graphical analysis was examined. Additionally, the effect of scan duration on the accuracy of analyses based on volumes of interest (VOls) and individual voxels was explored. Methods: Ten healthy male volunteers underwent bolus-injection F-18-CPFPX PET (90 min). The data were analyzed using a 2-tissue-compartment model and graphical analysis. Voxelwise graphical analysis was performed with and without preceding spatial gaussian smoothing. Results: Voxelwise graphical analysis yielded high-quality parametric images. However, voxelwise graphical analysis suffered from a negative bias (mean bias in cortical regions, -9.6% to -7.5%), which could be attenuated considerably by spatial smoothing (using a kernel of 5 mm in full width at half maximum, bias of -4.0% to -1.9%). Shortening the total scan duration to 60 min had minor effects on the accuracy of VOI-based analysis (15 VOls x 10 subjects); the resulting error only occasionally exceeded +/-5% in individual regions (n = 6 for 2-tissue-compartment model, n = 10 for VOI-based graphical analysis, always within +/-7.5%). Quantification accuracy was acceptable with scan durations of 60 and 75 min in voxelwise graphical analysis with spatial smoothing (mean bias in cortical regions, -8.4% to -5.9%) and without spatial smoothing (bias, -9.2% to - 11.6%), respectively. Conclusion: High-quality DVt parametric images of F-18-CPFPX can be generated by voxelwise graphical analysis. The noise-dependent negative bias of voxelwise graphical analysis is greatly reduced by spatial smoothing. A shortened scan of 60 min will enhance the clinical applicability of F-18-CPFPX PET. |