Untersuchungen an einer Folienisolierung in einem horizontalen Druckrohr
Untersuchungen an einer Folienisolierung in einem horizontalen Druckrohr
In a high-pressure gas duct a steel foil insulation, especially devised for HHT applications, was investigated in a horizontal pressure pipe under pressures between 1 bar and 4o bars and temperatures upto 4oo °C. Air and helium were used as testing gases. It was shown that the free convection of gas...
Saved in:
Personal Name(s): | Bröckerhoff, P. |
---|---|
Scholz, F. | |
Contributing Institute: |
Publikationen vor 2000; PRE-2000; Retrocat |
Imprint: |
Jülich
Kernforschungsanlage Jülich GmbH, Zentralbiliothek, Verlag
1974
|
Physical Description: |
126 p. |
Document Type: |
Report Book |
Research Program: |
Addenda |
Series Title: |
Berichte der Kernforschungsanlage Jülich
1109 |
Link: |
OpenAccess |
Publikationsportal JuSER |
In a high-pressure gas duct a steel foil insulation, especially devised for HHT applications, was investigated in a horizontal pressure pipe under pressures between 1 bar and 4o bars and temperatures upto 4oo °C. Air and helium were used as testing gases. It was shown that the free convection of gases in the circumferential gaps which were first supposed to be harmless, caused undue asymmetries in the distribution of temperatures and heat fluxes. After elimination or decrease in dimension ofthese gaps very satisfying results were achieved especially for helium. |