This title appears in the Scientific Report :
2020
Please use the identifier:
http://dx.doi.org/10.1615/TelecomRadEng.v78.i18.30 in citations.
WGM DIELECTRIC RESONATOR WITH CAPILLARY FOR MICROWAVE CHARACTERIZATION OF LIQUIDS
WGM DIELECTRIC RESONATOR WITH CAPILLARY FOR MICROWAVE CHARACTERIZATION OF LIQUIDS
The microwave characterization technique for the investigation of liquids of small volumes is presented. The technique is developed on the basis of a high-quality whispering gallery mode quartz resonator with a capillary placed in the hole of the resonator in the axial direction. The optimal inner c...
Saved in:
Personal Name(s): | Gubin, Alexey (Corresponding author) |
---|---|
Lavrinovich, A. A. / Protsenko, I. А. / Barannik, A. A. / Vitusevich, S. | |
Contributing Institute: |
Bioelektronik; ICS-8 |
Published in: | Telecommunications and radio engineering, 78 (2019) 18, S. 1651 - 1657 |
Imprint: |
New York, NY
Scripta Technica, Inc.
2019
|
DOI: |
10.1615/TelecomRadEng.v78.i18.30 |
Document Type: |
Journal Article |
Research Program: |
Controlling Configuration-Based Phenomena |
Publikationsportal JuSER |
The microwave characterization technique for the investigation of liquids of small volumes is presented. The technique is developed on the basis of a high-quality whispering gallery mode quartz resonator with a capillary placed in the hole of the resonator in the axial direction. The optimal inner capillary diameter was determined by experimental data obtained in Ka-band for the aqueous solution of glucose filling. The measurements of the bovine serum albumin and lactalbumin solutions confirm the applicability of the technique for studies of the biological liquids. |