Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate
Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate
Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexib...
Saved in:
Personal Name(s): | Choi, Chang-Hoon (Corresponding author) |
---|---|
Felder, Tim / Felder, Jörg / Tellmann, Lutz / Hong, Suk-Min / Wegener, Hans-Peter / Shah, Nadim Jon / Ziemons, Karl | |
Contributing Institute: |
Physik der Medizinischen Bildgebung; INM-4 JARA-BRAIN; JARA-BRAIN Jara-Institut Quantum Information; INM-11 |
Published in: | Physics in medicine and biology, 65 (2020) 11, S. 115005 |
Imprint: |
Bristol
IOP Publ.
2020
|
DOI: |
10.1088/1361-6560/ab87f8 |
PubMed ID: |
32268314 |
Document Type: |
Journal Article |
Research Program: |
Neuroimaging |
Link: |
OpenAccess OpenAccess |
Publikationsportal JuSER |
Please use the identifier: http://dx.doi.org/10.1088/1361-6560/ab87f8 in citations.
Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future. |