This title appears in the Scientific Report :
2021
Please use the identifier:
http://hdl.handle.net/2128/27177 in citations.
Please use the identifier: http://dx.doi.org/10.1016/j.apenergy.2020.116191 in citations.
Working Zone for a Least Squares Support Vector Machine in the Modeling of Polymer Electrolyte Fuel Cell Voltage
Working Zone for a Least Squares Support Vector Machine in the Modeling of Polymer Electrolyte Fuel Cell Voltage
The least squares support vector machine method has been successfully applied to modeling the transient behavior of polymer electrolyte fuel cells; this paper analyzes the credibility and definition of its reliable working zone when dealing with multiple load changes. The transient model based on th...
Saved in:
Personal Name(s): | Zou, Wei (Corresponding author) |
---|---|
Froning, Dieter / Shi, Yan / Lehnert, Werner | |
Contributing Institute: |
Elektrochemische Verfahrenstechnik; IEK-14 |
Published in: | Applied energy, 283 (2021) S. 116191 - |
Imprint: |
Amsterdam [u.a.]
Elsevier Science
2021
|
DOI: |
10.1016/j.apenergy.2020.116191 |
Document Type: |
Journal Article |
Research Program: |
Chemische Energieträger |
Link: |
Published on 2020-12-01. Available in OpenAccess from 2022-12-01. |
Publikationsportal JuSER |
Please use the identifier: http://dx.doi.org/10.1016/j.apenergy.2020.116191 in citations.
The least squares support vector machine method has been successfully applied to modeling the transient behavior of polymer electrolyte fuel cells; this paper analyzes the credibility and definition of its reliable working zone when dealing with multiple load changes. The transient model based on the least squares support vector machine is initially established. Then, the effects of the fuel cell system’s setup and exterior load behavior on the transient model are investigated. Artificial data from experimentally-validated Simulink simulations are used, by which extreme working conditions could be taken into account. We found that the fuel cell system’s setup with intensive sampling brings about better model performance than that with a sparse sampling interval, as sharp peaks are well characterized when intensive sampling is applied and more information on the fuel cell system is provided to the transient model. Furthermore, the performance of the transient model is better when smoother load changes are imposed on the system, and so a large ramp time and small ramp value are preferable. A working zone for a least squares support vector machine to model polymer electrolyte fuel cell is defined, for which an absolute error is used. Based on the acceptable level of error in the fuel cell system, a set of feasible combinations of its setup and exterior load changes is regulated. Accuracy in the transient model is achieved when the fuel cell runs within the working domain. |