Thermal analysis. E. pulse method of measuring basic thermophysical parameters.
Saved in:
Personal Name(s): | Kubicar, L. |
---|---|
Imprint: |
Amsterdam :
Elsevier,
1990.
|
Physical Description: |
XX, 341 S. |
Note: |
englisch |
ISBN: |
9780444988515 9780444417350 8022400858 0444988513 0444417354 9788022400855 |
Series Title: |
Wilson and Wilson's comprehensive analytical chemistry ;
12E. |
Keywords: |
measurement of thermophysical parameters heat loss from the sample surface contact between two bodies heat pulse width real heat sources silmultaneous effect of heat loss, the heat capacity or the heat sources and the contact thermal resistance on the measurement effect of real thermometers effect of the sample holder sample temperature stability measurement of thermophysical parameters under industrial conditions pulse method of measuring thermophysical parameters of thin metal foils computer programs |
Subject (ZB): | |
Classification: | |
Shelf Classification: |
LEADER | 01787cam a2200493 n 4500 | ||
---|---|---|---|
001 | 132444 | ||
005 | 20070928093700.0 | ||
008 | r1990 | ||
020 | |a 0444988513 | ||
020 | |a 0444417354 | ||
020 | |a 8022400858 | ||
035 | |a (Sirsi) a117676 | ||
084 | 0 | |a CTL - Thermal analysis |2 ZB | |
084 | 0 | |a CHXP - Thermochemistry |2 ZB | |
084 | 0 | |a CTA - Chemical analysis - comprehensive works |2 ZB | |
084 | 1 | |a CTA - Chemische Analyse - Handbücher, Serien |2 LS | |
245 | 0 | 0 | |a Thermal analysis. |n E. |p pulse method of measuring basic thermophysical parameters. |
260 | |a Amsterdam : |b Elsevier, |c 1990. | ||
300 | |a XX, 341 S. | ||
490 | 0 | |a Wilson and Wilson's comprehensive analytical chemistry ; |v 12E. | |
500 | |a englisch | ||
596 | |a 1 | ||
650 | 4 | |a thermal analysis | |
653 | |a measurement of thermophysical parameters | ||
653 | |a heat loss from the sample surface | ||
653 | |a contact between two bodies | ||
653 | |a heat pulse width | ||
653 | |a real heat sources | ||
653 | |a silmultaneous effect of heat loss, | ||
653 | |a the heat capacity or the heat sources | ||
653 | |a and the contact thermal resistance on the measurement | ||
653 | |a effect of real thermometers | ||
653 | |a effect of the sample holder | ||
653 | |a sample temperature stability | ||
653 | |a measurement of thermophysical parameters | ||
653 | |a under industrial conditions | ||
653 | |a pulse method of measuring thermophysical parameters | ||
653 | |a of thin metal foils | ||
653 | |a computer programs | ||
700 | 1 | |a Kubicar, L. | |
900 | |a B 001049'01'-012E | ||
900 | |a CTA 007-12E | ||
908 | |a Monographie, Sammelwerk | ||
949 | |a CTA 007-12E |w LC |c 1 |i 1090104982 |d 16/10/2007 |l STACKS |m ZB |r Y |s Y |t ZBB |u 25/3/2009 |x ZB-C |1 PRINT |